J&M Eastern Group is a Rittal supplier in Malaysia that specialises in Rittal Products. As one of the top Rittal partner and reseller in Malaysia, we carry a wide range of Rittal products such as enclosures, power distributions, climate control, and IT infrastructure to meet your requirements and quickly respond to the demands of your business. Our team is well experienced with Rittal products, solutions and services.

Rittal Home. Complex made simple – the guiding principle that makes Rittal perfect partner for you. – Enclosures, Power distribution, Climate control, IT infrastructure, Software & services, Automation.

TopTherm fan-and-filter units with EC technology

Energy-efficient version of the RTT fan-and-filter units with EC technology. From 180 m³/h with integral control interface (0-10 V / PWM input and tachosignal output) to regulate and monitor the fan.

TopTherm fan-and-filter units with EC technology comparison

Rittal SK 3238500
Rittal SK 3238500

Article number:
SK 3238.500
Design
wall-mounted

EC

Product description
Energy-efficient version of the TopTherm fan-and-filter units with diagonal fan technology. For controlling and monitoring fans 3240.50x to 3245.51x. The fan may be activated via the control interface with tacho signal output integrated as standard, and monitoring of the fan speed and function is supported.
Colour
RAL 7035
Supply includes
Complete unit ready to install, including chopped-fibre filter mat
Fan
Diagonal, EC motor
Air throughput, unimpeded airflow (with chopped-fibre filter)
At 50 Hz: 52 m³/h

At 60 Hz: 52 m³/h

Air throughput, unimpeded airflow (with pleated filter)
At 50 Hz: 63 m³/h

At 60 Hz: 70 m³/h

Air throughput with outlet filter including chopped-fibre filter mat (quantity x order number)
1 x 3238200: 36 m³/h
2 x 3238200: 46 m³/h
Rated operating voltage
200 V - 240 V, 1~, 50 Hz/60 Hz
Power consumption Pel
At 50 Hz: 5.8 W

At 60 Hz: 5.8 W

Rated current max.
At 50 Hz: 0.045 A

At 60 Hz: 0.045 A

Dimensions
Width: 148.5 mm

Height: 148.5 mm

Installation depth
58.5 mm
Mounting cut-out
Cut-out width: 124 mm

Cut-out height: 124 mm

IP protection category to IEC 60 529
IP54 with chopped-fibre filter/pleated filter
IP56 with chopped-fibre filter/pleated filter and hose-proof hood
Protection category NEMA
Type 12 with chopped-fibre filter/pleated filter
Type 3
Type 3R
Type 4
Type 4X with chopped-fibre filter/pleated filter and hose-proof hood
Pre-fuse
Miniature circuit-breaker/fuse: 6 A
Note
To increase the air throughput, a pleated filter may optionally be used (see characteristic curve). Suitable for use with fan-and-filter units, roof-mounted fans and outlet filters.
For even more efficient operation or for monitoring the fan-and-filter units, we recommend the use of the EC speed control for EC fan-and-filter units (from an air throughput of 180 m³/h).
Operating temperature range
-20 °C...55 °C
Storage temperature range
-30 °C...70 °C
Noise level
At 50 Hz: 49 dB(A)

At 60 Hz: 49 dB(A)

Weight/pack
0.62 kg
Packs of
1 pc(s).
Customs tariff number
84145915
EAN
4028177664128
ETIM 8
EC000320
ETIM 7.0
EC000320
ECLASS 8.0
27180716
Product description
SK Fan-and-filter unit TopTherm, 52 m³/h, 200-240 V, 1~, 50/60 Hz, WHD: 148.5 x 148.5 x 16 mm, EC technology
Rittal SK 3239500
Rittal SK 3239500

Article number:
SK 3239.500
Design
wall-mounted

EC

Product description
Energy-efficient version of the TopTherm fan-and-filter units with diagonal fan technology. For controlling and monitoring fans 3240.50x to 3245.51x. The fan may be activated via the control interface with tacho signal output integrated as standard, and monitoring of the fan speed and function is supported.
Colour
RAL 7035
Supply includes
Complete unit ready to install, including chopped-fibre filter mat
Fan
Diagonal, EC motor
Air throughput, unimpeded airflow (with chopped-fibre filter)
At 50 Hz: 100 m³/h

At 60 Hz: 100 m³/h

Air throughput, unimpeded airflow (with pleated filter)
At 50 Hz: 110 m³/h

At 60 Hz: 125 m³/h

Air throughput with outlet filter including chopped-fibre filter mat (quantity x order number)
1 x 3239200: 74 m³/h
2 x 3239200: 84 m³/h
Rated operating voltage
200 V - 240 V, 1~, 50 Hz/60 Hz
Power consumption Pel
At 50 Hz: 5.8 W

At 60 Hz: 5.8 W

Rated current max.
At 50 Hz: 0.045 A

At 60 Hz: 0.045 A

Dimensions
Width: 204 mm

Height: 204 mm

Installation depth
90 mm
Mounting cut-out
Cut-out width: 177 mm

Cut-out height: 177 mm

IP protection category to IEC 60 529
IP54 with chopped-fibre filter/pleated filter
IP55 with pleated filter and absorber mat
IP56 with chopped-fibre filter/pleated filter and hose-proof hood
Protection category NEMA
Type 12 with chopped-fibre filter/pleated filter
Type 3
Type 3R
Type 4
Type 4X with chopped-fibre filter/pleated filter and hose-proof hood
Pre-fuse
Miniature circuit-breaker/fuse: 6 A
Note
To increase the air throughput, a pleated filter may optionally be used (see characteristic curve). Suitable for use with fan-and-filter units, roof-mounted fans and outlet filters.
For even more efficient operation or for monitoring the fan-and-filter units, we recommend the use of the EC speed control for EC fan-and-filter units (from an air throughput of 180 m³/h).
Operating temperature range
-20 °C...55 °C
Storage temperature range
-30 °C...70 °C
Noise level
At 50 Hz: 53 dB(A)

At 60 Hz: 53 dB(A)

Weight/pack
0.91 kg
Packs of
1 pc(s).
Customs tariff number
84145915
EAN
4028177664135
ETIM 8
EC000320
ETIM 7.0
EC000320
ECLASS 8.0
27180716
Product description
SK Fan-and-filter unit TopTherm, 100 m³/h, 200-240 V, 1~, 50/60 Hz, WHD: 204 x 204 x 24 mm, EC technology
Rittal SK 3240500
Rittal SK 3240500

Article number:
SK 3240.500
Design
wall-mounted

EC

Product description
Energy-efficient version of the TopTherm fan-and-filter units with diagonal fan technology. For controlling and monitoring fans 3240.50x to 3245.51x. The fan may be activated via the control interface with tacho signal output integrated as standard, and monitoring of the fan speed and function is supported.
Colour
RAL 7035
Supply includes
Complete unit ready to install, including chopped-fibre filter mat
Fan
Diagonal, EC motor
Air throughput, unimpeded airflow (with chopped-fibre filter)
At 50 Hz: 175 m³/h

At 60 Hz: 175 m³/h

Air throughput, unimpeded airflow (with pleated filter)
At 50 Hz: 218 m³/h

At 60 Hz: 188 m³/h

Air throughput with outlet filter including chopped-fibre filter mat (quantity x order number)
1 x 3240200: 130 m³/h
2 x 3240200: 159 m³/h
Rated operating voltage
200 V - 240 V, 1~, 50 Hz/60 Hz
Power consumption Pel
At 50 Hz: 11 W

At 60 Hz: 11 W

Rated current max.
At 50 Hz: 0.12 A

At 60 Hz: 0.15 A

Dimensions
Width: 255 mm

Height: 255 mm

Installation depth
107 mm
Mounting cut-out
Cut-out width: 224 mm

Cut-out height: 224 mm

IP protection category to IEC 60 529
IP54 with chopped-fibre filter/pleated filter
IP55 with pleated filter and absorber mat
IP56 with chopped-fibre filter/pleated filter and hose-proof hood
Protection category NEMA
Type 12 with chopped-fibre filter/pleated filter
Type 3
Type 3R
Type 4
Type 4X with chopped-fibre filter/pleated filter and hose-proof hood
Control interface
Yes
Pre-fuse
Miniature circuit-breaker/fuse: 6 A
Note
To increase the air throughput, a pleated filter may optionally be used (see characteristic curve). Suitable for use with fan-and-filter units, roof-mounted fans and outlet filters.
For even more efficient operation or for monitoring the fan-and-filter units, we recommend the use of the EC speed control for EC fan-and-filter units (from an air throughput of 180 m³/h).
Operating temperature range
-25 °C...55 °C
Storage temperature range
-25 °C...70 °C
Noise level
At 50 Hz: 47 dB(A)

At 60 Hz: 47 dB(A)

Weight/pack
2.01 kg
Packs of
1 pc(s).
Customs tariff number
84145915
EAN
4028177664142
ETIM 8
EC000320
ETIM 7.0
EC000320
ECLASS 8.0
27180716
Product description
SK Fan-and-filter unit TopTherm, 175 m³/h, 200-240 V, 1~, 50/60 Hz, WHD: 255 x 255 x 25 mm, EC technology
Rittal SK 3241500
Rittal SK 3241500

Article number:
SK 3241.500
Design
wall-mounted

null

Product description
Energy-efficient version of the TopTherm fan-and-filter units with diagonal fan technology. For controlling and monitoring fans 3240.50x to 3245.51x. The fan may be activated via the control interface with tacho signal output integrated as standard, and monitoring of the fan speed and function is supported.
Colour
RAL 7035
Supply includes
Complete unit ready to install, including chopped-fibre filter mat
Fan
Diagonal, EC motor
Air throughput, unimpeded airflow (with chopped-fibre filter)
At 50 Hz: 225 m³/h

At 60 Hz: 225 m³/h

Air throughput, unimpeded airflow (with pleated filter)
At 50 Hz: 272 m³/h

At 60 Hz: 272 m³/h

Air throughput with outlet filter including chopped-fibre filter mat (quantity x order number)
1 x 3240200: 171 m³/h
2 x 3240200: 200 m³/h
Rated operating voltage
200 V - 240 V, 1~, 50 Hz/60 Hz
Power consumption Pel
At 50 Hz: 11 W

At 60 Hz: 11 W

Rated current max.
At 50 Hz: 0.17 A

At 60 Hz: 0.15 A

Dimensions
Width: 255 mm

Height: 255 mm

Installation depth
107 mm
Mounting cut-out
Cut-out width: 224 mm

Cut-out height: 224 mm

IP protection category to IEC 60 529
IP54 with chopped-fibre filter/pleated filter
IP55 with pleated filter and absorber mat
IP56 with chopped-fibre filter/pleated filter and hose-proof hood
Protection category NEMA
Type 12 with chopped-fibre filter/pleated filter
Type 3
Type 3R
Type 4
Type 4X with chopped-fibre filter/pleated filter and hose-proof hood
Control interface
Yes
Pre-fuse
Miniature circuit-breaker/fuse: 6 A
Note
To increase the air throughput, a pleated filter may optionally be used (see characteristic curve). Suitable for use with fan-and-filter units, roof-mounted fans and outlet filters.
For even more efficient operation or for monitoring the fan-and-filter units, we recommend the use of the EC speed control for EC fan-and-filter units (from an air throughput of 180 m³/h).
Operating temperature range
-25 °C...55 °C
Storage temperature range
-25 °C...70 °C
Noise level
At 50 Hz: 52 dB(A)

At 60 Hz: 52 dB(A)

Weight/pack
1.98 kg
Packs of
1 pc(s).
Customs tariff number
84145915
EAN
4028177652026
ETIM 8
EC000320
ETIM 7.0
EC000320
ECLASS 8.0
27180716
Product description
SK Fan-and-filter unit TopTherm, 225 m³/h, 200-240 V, 1~, 50/60 Hz, WHD: 255 x 255 x 25 mm, EC technology
Rittal SK 3243500
Rittal SK 3243500

Article number:
SK 3243.500
Design
wall-mounted

null

Product description
Energy-efficient version of the TopTherm fan-and-filter units with diagonal fan technology. For controlling and monitoring fans 3240.50x to 3245.51x. The fan may be activated via the control interface with tacho signal output integrated as standard, and monitoring of the fan speed and function is supported.
Colour
RAL 7035
Supply includes
Complete unit ready to install, including chopped-fibre filter mat
Fan
Diagonal, EC motor
Air throughput, unimpeded airflow (with chopped-fibre filter)
At 50 Hz: 540 m³/h

At 60 Hz: 540 m³/h

Air throughput, unimpeded airflow (with pleated filter)
At 50 Hz: 625 m³/h

At 60 Hz: 716 m³/h

Air throughput with outlet filter including chopped-fibre filter mat (quantity x order number)
1 x 3243200: 405 m³/h
2 x 3243200: 475 m³/h
Rated operating voltage
200 V - 240 V, 1~, 50 Hz/60 Hz
Power consumption Pel
At 50 Hz: 51 W

At 60 Hz: 51 W

Rated current max.
At 50 Hz: 0.5 A

At 60 Hz: 0.5 A

Dimensions
Width: 323 mm

Height: 323 mm

Installation depth
118.5 mm
Mounting cut-out
Cut-out width: 292 mm

Cut-out height: 292 mm

IP protection category to IEC 60 529
IP54 with chopped-fibre filter/pleated filter
IP55 with pleated filter and absorber mat
IP56 with chopped-fibre filter/pleated filter and hose-proof hood
Protection category NEMA
Type 12 with chopped-fibre filter/pleated filter
Type 3
Type 3R
Type 4
Type 4X with chopped-fibre filter/pleated filter and hose-proof hood
Control interface
Yes
Pre-fuse
Miniature circuit-breaker/fuse: 6 A
Note
To increase the air throughput, a pleated filter may optionally be used (see characteristic curve). Suitable for use with fan-and-filter units, roof-mounted fans and outlet filters.
For even more efficient operation or for monitoring the fan-and-filter units, we recommend the use of the EC speed control for EC fan-and-filter units (from an air throughput of 180 m³/h).
Operating temperature range
-25 °C...55 °C
Storage temperature range
-25 °C...70 °C
Noise level
At 50 Hz: 63 dB(A)

At 60 Hz: 63 dB(A)

Weight/pack
2.92 kg
Packs of
1 pc(s).
Customs tariff number
84145915
EAN
4028177652156
ETIM 8
EC000320
ETIM 7.0
EC000320
ECLASS 8.0
27180716
Product description
SK Fan-and-filter unit TopTherm, 540 m³/h, 200-240 V, 1~, 50/60 Hz, WHD: 323 x 323 x 25 mm, EC technology
Rittal SK 3244500
Rittal SK 3244500

Article number:
SK 3244.500
Design
wall-mounted

EC

Product description
Energy-efficient version of the TopTherm fan-and-filter units with diagonal fan technology. For controlling and monitoring fans 3240.50x to 3245.51x. The fan may be activated via the control interface with tacho signal output integrated as standard, and monitoring of the fan speed and function is supported.
Colour
RAL 7035
Supply includes
Complete unit ready to install, including chopped-fibre filter mat
Fan
Diagonal, EC motor
Air throughput, unimpeded airflow (with chopped-fibre filter)
At 50 Hz: 700 m³/h

At 60 Hz: 700 m³/h

Air throughput, unimpeded airflow (with pleated filter)
At 50 Hz: 855 m³/h

At 60 Hz: 855 m³/h

Air throughput with outlet filter including chopped-fibre filter mat (quantity x order number)
1 x 3243200: 485 m³/h
2 x 3243200: 570 m³/h
Rated operating voltage
200 V - 240 V, 1~, 50 Hz/60 Hz
Power consumption Pel
At 50 Hz: 80 W

At 60 Hz: 80 W

Rated current max.
At 50 Hz: 0.7 A

At 60 Hz: 0.7 A

Dimensions
Width: 323 mm

Height: 323 mm

Installation depth
130.5 mm
Mounting cut-out
Cut-out width: 292 mm

Cut-out height: 292 mm

IP protection category to IEC 60 529
IP54 with chopped-fibre filter/pleated filter
IP55 with pleated filter and absorber mat
IP56 with chopped-fibre filter/pleated filter and hose-proof hood
Protection category NEMA
Type 12 with chopped-fibre filter/pleated filter
Type 3
Type 3R
Type 4
Type 4X with chopped-fibre filter/pleated filter and hose-proof hood
Control interface
Yes
Pre-fuse
Miniature circuit-breaker/fuse: 6 A
Note
To increase the air throughput, a pleated filter may optionally be used (see characteristic curve). Suitable for use with fan-and-filter units, roof-mounted fans and outlet filters.
For even more efficient operation or for monitoring the fan-and-filter units, we recommend the use of the EC speed control for EC fan-and-filter units (from an air throughput of 180 m³/h).
Operating temperature range
-25 °C...55 °C
Storage temperature range
-25 °C...70 °C
Noise level
At 50 Hz: 64 dB(A)

At 60 Hz: 64 dB(A)

Weight/pack
2.7 kg
Packs of
1 pc(s).
Customs tariff number
84145915
EAN
4028177652217
ETIM 8
EC000320
ETIM 7.0
EC000320
ECLASS 8.0
27180716
Product description
SK fan and filter units TopTherm, 700 m³/h, 200-240 V, 1~, 50/60 Hz, WHD: 323 x 323 x 25 mm, EC-Technology
Rittal SK 3245500
Rittal SK 3245500

Article number:
SK 3245.500
Design
wall-mounted

EC

Product description
Energy-efficient version of the TopTherm fan-and-filter units with diagonal fan technology. For controlling and monitoring fans 3240.50x to 3245.51x. The fan may be activated via the control interface with tacho signal output integrated as standard, and monitoring of the fan speed and function is supported.
Colour
RAL 7035
Supply includes
Complete unit ready to install, including chopped-fibre filter mat
Fan
Diagonal, EC motor
Air throughput, unimpeded airflow (with chopped-fibre filter)
At 50 Hz: 890 m³/h

At 60 Hz: 890 m³/h

Air throughput, unimpeded airflow (with pleated filter)
At 50 Hz: 1,125 m³/h

At 60 Hz: 1,125 m³/h

Air throughput with outlet filter including chopped-fibre filter mat (quantity x order number)
1 x 3243200: 630 m³/h
2 x 3243200: 770 m³/h
Rated operating voltage
200 V - 240 V, 1~, 50 Hz/60 Hz
Power consumption Pel
At 50 Hz: 165 W

At 60 Hz: 165 W

Rated current max.
At 50 Hz: 1.33 A

At 60 Hz: 1.33 A

Dimensions
Width: 323 mm

Height: 323 mm

Installation depth
130.5 mm
Mounting cut-out
Cut-out width: 292 mm

Cut-out height: 292 mm

IP protection category to IEC 60 529
IP51 with chopped-fibre filter/pleated filter
IP52 with pleated filter and absorber mat
IP56 with chopped-fibre filter/pleated filter and hose-proof hood
Protection category NEMA
Type 1
Type 12
Type 3
Type 3R with chopped-fibre filter/pleated filter and hose-proof hood
Control interface
Yes
Pre-fuse
Miniature circuit-breaker/fuse: 4 A
Note
To increase the air throughput, a pleated filter may optionally be used (see characteristic curve). Suitable for use with fan-and-filter units, roof-mounted fans and outlet filters.
For even more efficient operation or for monitoring the fan-and-filter units, we recommend the use of the EC speed control for EC fan-and-filter units (from an air throughput of 180 m³/h).
Operating temperature range
-25 °C...55 °C
Storage temperature range
-25 °C...70 °C
Noise level
At 50 Hz: 72 dB(A)

At 60 Hz: 72 dB(A)

Weight/pack
3.46 kg
Packs of
1 pc(s).
Customs tariff number
84145915
EAN
4028177652262
ETIM 8
EC000320
ETIM 7.0
EC000320
ECLASS 8.0
27180716
Product description
SK Fan-and-filter unit TopTherm, 890 m³/h, 200-240 V, 1~, 50/60 Hz, WHD: 323 x 323 x 25 mm, EC technology
Rittal SK 3245508
Rittal SK 3245508

Article number:
SK 3245.508
Design
wall-mounted

EC

Product description
Energy-efficient version of the TopTherm fan-and-filter units with diagonal fan technology. For controlling and monitoring fans 3240.50x to 3245.51x. The fan may be activated via the control interface with tacho signal output integrated as standard, and monitoring of the fan speed and function is supported.
Colour
RAL 9005
Supply includes
Complete unit ready to install, including chopped-fibre filter mat
Fan
Diagonal, EC motor
Air throughput, unimpeded airflow (with chopped-fibre filter)
At 50 Hz: 890 m³/h

At 60 Hz: 890 m³/h

Air throughput, unimpeded airflow (with pleated filter)
At 50 Hz: 1,125 m³/h

At 60 Hz: 1,125 m³/h

Air throughput with outlet filter including chopped-fibre filter mat (quantity x order number)
1 x 3243208: 630 m³/h
2 x 3243208: 770 m³/h
Rated operating voltage
200 V - 240 V, 1~, 50 Hz/60 Hz
Power consumption Pel
At 50 Hz: 165 W

At 60 Hz: 165 W

Rated current max.
At 50 Hz: 1.33 A

At 60 Hz: 1.33 A

Dimensions
Width: 323 mm

Height: 323 mm

Installation depth
130.5 mm
Mounting cut-out
Cut-out width: 292 mm

Cut-out height: 292 mm

IP protection category to IEC 60 529
IP51 with chopped-fibre filter/pleated filter
IP52 with pleated filter and absorber mat
IP56 with chopped-fibre filter/pleated filter and hose-proof hood
Protection category NEMA
Type 1
Type 12
Type 3
Type 3R with chopped-fibre filter/pleated filter and hose-proof hood
Control interface
Yes
Pre-fuse
Miniature circuit-breaker/fuse: 4 A
Note
To increase the air throughput, a pleated filter may optionally be used (see characteristic curve). Suitable for use with fan-and-filter units, roof-mounted fans and outlet filters.
For even more efficient operation or for monitoring the fan-and-filter units, we recommend the use of the EC speed control for EC fan-and-filter units (from an air throughput of 180 m³/h).
Operating temperature range
-25 °C...55 °C
Storage temperature range
-25 °C...70 °C
Noise level
At 50 Hz: 72 dB(A)

At 60 Hz: 72 dB(A)

Weight/pack
3.46 kg
Packs of
1 pc(s).
Customs tariff number
84145915
EAN
4028177663909
ETIM 8
EC000320
ETIM 7.0
EC000320
ECLASS 8.0
27180716
Product description
SK Fan-and-filter unit TopTherm, 890 m³/h, 200-240 V, 1~, 50/60 Hz, WHD: 323 x 323 x 25 mm, EC technology
Rittal SK 3245510
Rittal SK 3245510

Article number:
SK 3245.510
Design
wall-mounted

EC

Product description
Energy-efficient version of the TopTherm fan-and-filter units with diagonal fan technology. For controlling and monitoring fans 3240.50x to 3245.51x. The fan may be activated via the control interface with tacho signal output integrated as standard, and monitoring of the fan speed and function is supported.
Colour
RAL 7035
Supply includes
Complete unit ready to install, including chopped-fibre filter mat
Fan
Diagonal, EC motor
Air throughput, unimpeded airflow (with chopped-fibre filter)
At 50 Hz: 890 m³/h

At 60 Hz: 890 m³/h

Air throughput, unimpeded airflow (with pleated filter)
At 50 Hz: 1,125 m³/h

At 60 Hz: 1,125 m³/h

Air throughput with outlet filter including chopped-fibre filter mat (quantity x order number)
1 x 3243200: 630 m³/h
2 x 3243200: 770 m³/h
Rated operating voltage
100 V - 130 V, 1~, 50 Hz/60 Hz
Power consumption Pel
At 50 Hz: 165 W

At 60 Hz: 165 W

Rated current max.
At 50 Hz: 2.1 A

At 60 Hz: 2.1 A

Dimensions
Width: 323 mm

Height: 323 mm

Installation depth
130.5 mm
Mounting cut-out
Cut-out width: 292 mm

Cut-out height: 292 mm

IP protection category to IEC 60 529
IP51 with chopped-fibre filter/pleated filter
IP52 with pleated filter and absorber mat
IP56 with chopped-fibre filter/pleated filter and hose-proof hood
Protection category NEMA
Type 1
Type 12
Type 3
Type 3R with chopped-fibre filter/pleated filter and hose-proof hood
Control interface
Yes
Pre-fuse
Miniature circuit-breaker/fuse: 6 A
Note
To increase the air throughput, a pleated filter may optionally be used (see characteristic curve). Suitable for use with fan-and-filter units, roof-mounted fans and outlet filters.
For even more efficient operation or for monitoring the fan-and-filter units, we recommend the use of the EC speed control for EC fan-and-filter units (from an air throughput of 180 m³/h).
Operating temperature range
-25 °C...55 °C
Storage temperature range
-25 °C...70 °C
Noise level
At 50 Hz: 72 dB(A)

At 60 Hz: 72 dB(A)

Weight/pack
3.76 kg
Packs of
1 pc(s).
Customs tariff number
84145915
EAN
4028177659018
ETIM 8
EC000320
ETIM 7.0
EC000320
ECLASS 8.0
27180716
Product description
SK Fan-and-filter unit TopTherm, 890 m³/h, 100-130 V, 1~, 50/60 Hz, WHD: 323 x 323 x 25 mm, EC technology
Rittal SK 3245518
Rittal SK 3245518

Article number:
SK 3245.518
Design
wall-mounted

EC

Product description
Energy-efficient version of the TopTherm fan-and-filter units with diagonal fan technology. For controlling and monitoring fans 3240.50x to 3245.51x. The fan may be activated via the control interface with tacho signal output integrated as standard, and monitoring of the fan speed and function is supported.
Colour
RAL 9005
Supply includes
Complete unit ready to install, including chopped-fibre filter mat
Fan
Diagonal, EC motor
Air throughput, unimpeded airflow (with chopped-fibre filter)
At 50 Hz: 890 m³/h

At 60 Hz: 890 m³/h

Air throughput, unimpeded airflow (with pleated filter)
At 50 Hz: 1,125 m³/h

At 60 Hz: 1,125 m³/h

Air throughput with outlet filter including chopped-fibre filter mat (quantity x order number)
1 x 3243208: 630 m³/h
2 x 3243208: 770 m³/h
Rated operating voltage
100 V - 130 V, 1~, 50 Hz/60 Hz
Power consumption Pel
At 50 Hz: 165 W

At 60 Hz: 165 W

Rated current max.
At 50 Hz: 2.1 A

At 60 Hz: 2.1 A

Dimensions
Width: 323 mm

Height: 323 mm

Installation depth
130.5 mm
Mounting cut-out
Cut-out width: 292 mm

Cut-out height: 292 mm

IP protection category to IEC 60 529
IP51 with chopped-fibre filter/pleated filter
IP52 with pleated filter and absorber mat
IP56 with chopped-fibre filter/pleated filter and hose-proof hood
Protection category NEMA
Type 1
Type 12
Type 3
Type 3R with chopped-fibre filter/pleated filter and hose-proof hood
Control interface
Yes
Pre-fuse
Miniature circuit-breaker/fuse: 6 A
Note
To increase the air throughput, a pleated filter may optionally be used (see characteristic curve). Suitable for use with fan-and-filter units, roof-mounted fans and outlet filters.
For even more efficient operation or for monitoring the fan-and-filter units, we recommend the use of the EC speed control for EC fan-and-filter units (from an air throughput of 180 m³/h).
Operating temperature range
-25 °C...55 °C
Storage temperature range
-25 °C...70 °C
Noise level
At 50 Hz: 72 dB(A)

At 60 Hz: 72 dB(A)

Weight/pack
3.76 kg
Packs of
1 pc(s).
Customs tariff number
84145915
EAN
4028177664111
ETIM 8
EC000320
ETIM 7.0
EC000320
ECLASS 8.0
27180716
Product description
SK Fan-and-filter unit TopTherm, 890 m³/h, 100-130 V, 1~, 50/60 Hz, WHD: 323 x 323 x 25 mm, EC technology

Get TopTherm fan-and-filter units with EC technology Pricing

To receive Rittal TopTherm fan-and-filter units with EC technology price, please send us a message >

Scroll to Top